Products
Products
0.03-8 mSelectable measuring range
IP67/IP68Outdoor and wet environments
Analog / RS485Multiple output interfaces
-20~70℃Industrial temperature range
Product Data
Use the filters to narrow sensing type, installation environment, and output requirements. The data table keeps core selection parameters visible for engineering comparison.
Type
Range
Protection Rating
All
| Model | Type | Center Frequency | Transmit Sensitivity | Receive Sensitivity | Ringing | Beam Angle | Measuring Range | Blind Zone | Angle | Repeatability | Operating Voltage | Action |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HC200F18GM-I/U-1000-V1
Built-in temperature compensationAdjustable detection rangeNickel-plated copper housing (stainless steel customizable)IP...
|
High Frequency | -- | -- | -- | -- | -- | 60-1000mm | 0~60mm | 10° | 0.003 | 10~30VDC or 15~30VDC | View |
|
HC200E12TR-2
Built-in temperature compensationAdjustable detection rangeNickel-plated copper housing (stainless steel customizable)IP...
|
Wind Speed | 200.0KHz±4% | -- | -- | 600us max | 10°±2° (-6dB) | -- | -- | 100°±15° | -- | -- | View |
|
HC40B18TR-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Integrated Transceiver | 40.0KHz±2% | 108dB min(40Khz 30cm 0dB=20ubar) | -80dB min(40Khz 30cm 0dB=10V/pa) | 1.2ms max | X-axis: 110±10°; Y-axis: 55±10° | -- | -- | 55*120° | -- | -- | View |
|
HC200E12TR-1T
Built-in temperature compensationAdjustable detection rangeNickel-plated copper housing (stainless steel customizable)IP...
|
Wind Speed | 200.0KHz±4% | -- | -- | 600us max | 10°±2° (-6dB) | -- | -- | 85°±15° | -- | -- | View |
|
HC40A25TR-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Integrated Transceiver | 40.0KHz±2% | 106dB min(40Khz 30cm 0dB=20ubar) | -78dB min(40Khz 30cm 0dB=10V/pa) | 1.2ms max | 35°±15° (-6dB) | -- | -- | 35°±15° | -- | -- | View |
|
HC200E12TR-5
Built-in temperature compensationAdjustable detection rangeNickel-plated copper housing (stainless steel customizable)IP...
|
Web Guiding | 200.0KHz±2% | -- | -- | 700us max | 8°±5° (-6dB) | -- | -- | 8±3° | -- | -- | View |
|
HC40A18TR-2
Eco-friendly materialsHigh sensitivityHigh reliability
|
Integrated Transceiver | 40.0KHz±2% | 98dB min(40Khz 30cm 0dB=20ubar) | -82dB min(40Khz 30cm 0dB=10V/pa) | 1.2ms max | 100°±15° (-6dB) | -- | -- | 100°±15° | -- | -- | View |
|
HC40A18TR-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Integrated Transceiver | 40.0KHz±2% | 100dB min(40Khz 30cm 0dB=20ubar) | -78dB min(40Khz 30cm 0dB=10V/pa) | 1.2ms max | 85°±15° (-6dB) | -- | -- | 85°±15° | -- | -- | View |
|
HC40A16TR-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Integrated Transceiver | 40.0KHz±2% | 103dB min(40Khz 30cm 0dB=20ubar) | -80dB min(40Khz 30cm 0dB=10V/pa) | 1.2ms max | 75°±15° (-6dB) | -- | -- | 80°±15° | -- | -- | View |
|
HC40A14TR-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Integrated Transceiver | 40.0KHz±2% | 100dB min(40Khz 30cm 0dB=20ubar) | -82dB min(40Khz 30cm 0dB=10V/pa) | 1.2ms max | 75°±15° (-6dB) | -- | -- | 75°±15° | -- | -- | View |
|
HC40A10TR-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Integrated Transceiver | 40.0KHz±2% | 98dB min(40Khz 30cm 0dB=20ubar) | -85dB min(40Khz 30cm 0dB=10V/pa) | 1.2ms max | 90°±15° (-6dB) | -- | -- | 90°±15° | -- | -- | View |
|
HC25A25T/R-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Separate Transmitter / Receiver | 25.0KHz±2% | 113dB min(25Khz 30cm 0dB=20ubar) | -67dB min(25Khz 30cm 0dB=10V/pa) | 1.2ms max | 35°±15° (-6dB) | -- | -- | 35°±15° | -- | -- | View |
|
HC23A25T/R-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Separate Transmitter / Receiver | 23.0KHz±2% | 113dB min(23Khz 30cm 0dB=20ubar) | -67dB min(23Khz 30cm 0dB=10V/pa) | 1.2ms max | 35°±15° (-6dB) | -- | -- | 35°±15° | -- | -- | View |
|
HC40A8TR-1
Eco-friendly materialsHigh sensitivityHigh reliability
|
Integrated Transceiver | 40.0KHz±2% | 93dB min(40Khz 30cm 0dB=20ubar) | -87dB min(40Khz 30cm 0dB=10V/pa) | 1.2ms max | 100°±15° (-6dB) | -- | -- | 100°±15° | -- | -- | View |
Beam Angle and Blind Zone Reference
A technical reference for beam angle, blind zone and installation distance to support model comparison within the same series.
Product Selection Tips
Compare measuring range, blind zone, protection rating and output interface first, then evaluate installation space, target material and environmental conditions.
Need Help Selecting the Right Model?
Tell us your target medium, measuring range, installation angle, output signal and required quantity. Our engineers will recommend a suitable model.